Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 1614, 2022 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-35102204

RESUMO

As the SARS-CoV-2 pandemic persists, methods that can quickly and reliably confirm infection and immune status is extremely urgently and critically needed. In this contribution we show that combining laser induced breakdown spectroscopy (LIBS) with machine learning can distinguish plasma of donors who previously tested positive for SARS-CoV-2 by RT-PCR from those who did not, with up to 95% accuracy. The samples were also analyzed by LIBS-ICP-MS in tandem mode, implicating a depletion of Zn and Ba in samples of SARS-CoV-2 positive subjects that inversely correlate with CN lines in the LIBS spectra.


Assuntos
COVID-19/sangue , COVID-19/diagnóstico , Imunidade , Lasers , Pandemias , SARS-CoV-2/imunologia , Espectrofotometria Atômica/métodos , Bário/análise , COVID-19/epidemiologia , COVID-19/virologia , Confiabilidade dos Dados , Análise Discriminante , Reações Falso-Negativas , Reações Falso-Positivas , Humanos , Aprendizado de Máquina , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , Sensibilidade e Especificidade , Zinco/análise
2.
Talanta ; 182: 253-258, 2018 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-29501149

RESUMO

In this paper, Nanoparticle-Enhanced Laser Induced Breakdown Spectroscopy is applied to transparent samples and gemstones with the aim to overcome the laser induced damage on the sample. We propose to deposit a layer of AuNPs on the sample surface by drying a colloidal solution before ablating the sample with a 532 nm pulsed laser beam. This procedure ensures that the most significant fraction of the beam, being in resonance with the AuNP surface plasmon, is mainly absorbed by the NP layer, which in turn results the breakdown to be induced on NPs rather than on the sample itself. The fast explosion of the NPs and the plasma induction allow the ablation and the transfer in the plasma phase of the portion of sample surface where the NPs were placed. The employed AuNPs are prepared in milliQ water without the use of any chemical stabilizers by Pulsed Laser Ablation in Liquids (PLAL), in order to obtain a strict control of composition and impurities, and to limit possible spectral interferences (except from Au emission lines). Therefore with this technique it is possible to obtain, together with the emission signal of Au (coming from atomized NPs), the emission spectrum of the sample, by limiting or avoiding the direct interaction of the laser pulse with the sample itself. This approach is extremely useful for the elemental analysis by laser ablation of high refractive index samples, where the laser pulse on an untreated surface can otherwise penetrate inside the sample, generate breakdown events below the superficial layer, and consequently cause cracks and other damage. The results obtained with NELIBS on high refractive index samples like glasses, tourmaline, aquamarine and ruby are very promising, and demonstrate the potentiality of this approach for precious gemstones analysis.

3.
Anal Chim Acta ; 813: 15-24, 2014 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-24528655

RESUMO

A modified version of the calibration-free (CF) method was applied to the analysis of a set of archaeological brooches made of various copper-based alloys and coming from the archaeological site of Egnatia (Apulia, Southern Italy). The developed methodology consists in determining the plasma temperature by reversing the set of equations employed in the usual CF algorithm, and it is thus referred to as "inverse method". The plasma temperature is determined for one certified standard, by using its known elemental composition as an input data, and then applied to the set of unknown samples to evaluate their composition in a CF mode. The feasibility of such an approach is demonstrated by comparing the results obtained with classical LIBS (drawing calibration lines with a series of matrix-matched certified standards) and with independent measurements performed with a conventional technique (LA-ICP-MS).

4.
Anal Chem ; 85(21): 10180-7, 2013 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-24090397

RESUMO

In this article, an increase of 1-2 orders of magnitude in laser-induced breakdown spectroscopy (LIBS) signals was obtained by depositing silver nanoparticles on metal samples. Nanoparticle-enhanced LIBS (NELIBS) was found to be a robust and flexible tool for the chemical analysis of metals because the sample emission signal did not appear to be affected much by the size and concentration of deposited nanoparticles (NPs) within the ranges of 10 nm for diameter and 1 order of magnitude for concentration. On the other hand, preliminary NELIBS tests on insulators and semiconductors did not show any significant enhancement with respect to conventional LIBS. In this article, we present a detailed investigation of the fundamental features of NELIBS spectra, in addition to some examples of analytical applications to the quantitative analysis of metal alloys.

5.
Phys Chem Chem Phys ; 15(9): 3083-92, 2013 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-23198287

RESUMO

Although the first nanoseconds to microseconds rule the resulting process yield of laser ablation in liquid, a comprehensive view involving combination of time-resolved measurement techniques is still lacking. In this paper, fundamental aspects of laser ablation of metals in water during the production of nanoparticles are discussed. Three fast diagnostic methods have been applied simultaneously. These are Optical Emission Spectroscopy for the plasma characterization, fast shadowgraph for plasma and cavitation bubble dynamics and laser scattering for the mechanisms of delivery of the produced materials in the liquid. Moreover, in order to validate the discussion, the effect on cavitation dynamics of the ablation of bulk and wire-shaped targets has been investigated together with the relative nanoparticles production yield. Unusual arrow-bow ejection phenomena between the cavitation bubble and the wire result in suppressed material back-deposition, causing efficient ejection of ablated matter into the liquid. The presented nanosecond and microsecond-resolved analysis allows estimating the timescale and role of the basic mechanisms involved in laser ablation in liquids as well as the thermodynamic characteristics of the processes.

6.
Environ Res ; 109(4): 413-20, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19272593

RESUMO

Soil is unanimously considered as one of the most important sink of heavy metals released by human activities. Heavy metal analysis of natural and polluted soils is generally conducted by the use of atomic absorption spectroscopy (AAS) or inductively coupled plasma optical emission spectroscopy (ICP-OES) on adequately obtained soil extracts. Although in recent years the emergent technique of laser-induced breakdown spectroscopy (LIBS) has been applied widely and with increasing success for the qualitative and quantitative analyses of a number of heavy metals in soil matrices with relevant simplification of the conventional methodologies, the technique still requires further confirmation before it can be applied fully successfully in soil analyses. The main objective of this work was to demonstrate that new developments in LIBS technique are able to provide reliable qualitative and quantitative analytical evaluation of several heavy metals in soils, with special focus on the element chromium (Cr), and with reference to the concentrations measured by conventional ICP spectroscopy. The preliminary qualitative LIBS analysis of five soil samples and one sewage sludge sample has allowed the detection of a number of elements including Al, Ca, Cr, Cu, Fe, Mg, Mn, Pb, Si, Ti, V and Zn. Of these, a quantitative analysis was also possible for the elements Cr, Cu, Pb, V and Zn based on the obtained linearity of the calibration curves constructed for each heavy metal, i.e., the proportionality between the intensity of the LIBS emission peaks and the concentration of each heavy metal in the sample measured by ICP. In particular, a triplet of emission lines for Cr could be used for its quantitative measurement. The consistency of experiments made on various samples was supported by the same characteristics of the laser-induced plasma (LIP), i.e., the typical linear distribution confirming the existence of local thermodynamic equilibrium (LTE) condition, and similar excitation temperatures and comparable electron number density measured for all samples. An index of the anthropogenic contribution of Cr in polluted soils was calculated in comparison to a non-polluted reference soil. Thus, the intensity ratios of the emission lines of heavy metal can be used to detect in few minutes the polluted areas for which a more detailed sampling and analysis can be useful.


Assuntos
Monitoramento Ambiental/métodos , Lasers , Metais Pesados/análise , Poluentes do Solo/análise , Análise Espectral/métodos , Cromo/análise , Humanos , Itália , Sensibilidade e Especificidade , Esgotos/química , Espectrofotometria Atômica , Análise Espectral/instrumentação , Análise Espectral/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA